Frameless shower doors fail at the details: a hinge set sized for the wrong glass weight, spacing that puts too much load on one panel, or a seal that closes the gap but not the deflection. The tools on this page turn dimensions into a starting specification, so a buyer can shortlist hardware before requesting a quotation.
Start with glass weight, not with hinge count
Hinge choice follows glass weight and door geometry. As a planning reference, 8 mm glass is roughly 20 kg per square metre, 10 mm is roughly 25 kg per square metre and 12 mm is roughly 30 kg per square metre. A 1,000 x 2,000 mm door in 10 mm glass is therefore around 50 kg before handles and fittings. Confirm the actual weight with the glass supplier, then compare it with the hinge torque rating and the maximum door width published for the model.
What the hinge calculator returns
| Input or output | Why it matters |
|---|---|
| Door width and height | Sets the glass area, the lever arm on the hinges and the practical hinge spacing. |
| Glass thickness | Changes weight per square metre and the hinge/clamp series that will fit the hole pattern. |
| Door type | A pivot door, a hinged door and a bi-fold panel carry load differently. |
| Glass weight | The first number to compare against the hinge torque rating. |
| Hinge count and spacing | A starting layout to check against the glass hole drawing and wall fixing. |
The output is a planning check, not a stamped engineering calculation. Wall substrate, stud position, glass hole tolerance, hinge model limits and local building rules still need confirmation before fabrication.
How to use the result
- Compare torque, not just finish. A heavy 12 mm door needs a hinge rated for the load; a lightweight 8 mm door may be over-specified by a heavy-duty model. Start from the shower hinge range and check the duty class before choosing a finish.
- Distribute hinges where the load is. Keep the top and bottom hinges close enough to the corners to control the panel, and confirm the spacing against the glass drawing. Uneven spacing is a common cause of sag.
- Add clamps and stabilizers for the fixed panels. Hinges carry the moving door; fixed glass needs glass clamps and, where the panel is tall or wide, a support bar or stabilizer.
- Close the enclosure with the right seal. A header, PVC or PC seal controls the gap and water deflection; it does not correct a hinge layout that is already overloaded.
Before you order: five checks
- Glass thickness, actual measured weight and hole pattern confirmed by the fabricator.
- Hinge torque rating and maximum door width checked against the calculated load.
- Wall fixing type confirmed: concrete, block, stud or a reinforced profile.
- Handle and knob position checked so the door does not hit the fixed panel or wall.
- Finish sample approved under the lighting used in the final installation.
Need a custom assembly?
If the calculator points to a non-standard door, send the drawing and target finish through the contact page. For a new part, start with the OEM and ODM process; for a mixed stock order, use the wholesale shower hardware page. More specification help is collected in the frameless hardware guide and the article index.
Last reviewed: 20 November 2026. Calculator outputs are planning guidance; confirm final hardware with the glass fabricator and project engineer.